FAQ

Breakdown

Reason

Eliminating method

Wind generator vibrating strongly

1. Guy wire is loose.

2. Fixed bolts of blades are loose.

3Blade is damaged by outside force.

4. Ices over on the surface of blades, and cause unbalance.

1. Tighten the steel wire rope appropriately.

2. Tighten the loose parts.

3. Replace a new one and adjust the rotor to balance state again.

4. Eliminate the attached ices.

Direction regulating is ineffective

1. There is too much greasy filth in the rotating body.

2. Rotating part is deformed by outside force.

3. The interspaces between vertical shaft and sleeve are too small, or there is no space for axial move.

1. Clear away the dirty filth, and make a lubricating maintenance.

2. Recover and correct the deformation.

3. Repair and enable the interspaces meet the requirement.

Unusual noise

1. Fixed parts is loose

2. Generator bearing is loose from its seat.

3. Generator bearing is damaged

4. Wind rotor is rubbing with other part.

1. Put the wind turbine down to the ground, check every fixed part, and take measures.

2. Find out the loose place, then repair and eliminate the trouble.

3. Replace the damaged bearing.

4. Check and eliminate the trouble.

The rotating speed of the wind rotor is reduced obviously

1. Blade pitch control is ineffective.

2. Stator winding is short –circuit or output circuit is short pass.

3. Break disk is rubbing.

4. Switch is set at “close” position:

1. Check and eliminate the trouble, then make lubrication and maintenance.

2. Find out short circuit position, separate the lines and isolate them...

3. Readjust the break gap.

4. Set switch at “open” position.

The output voltage of the generator is low

1. The rotating speed of the generator is low.

2. Permanent magnet rotor has lost its magnet.

3. There is short circuit in three-phase stator winding.

4. The conductivity of the connect point between slip ring and output circuit is weak.

5. There is short circuit in rectifier.

6. Circuit line is too long, or the diameter of wire is too thin. 

1. Find out the reason, restoring to normal rotating speed.

2. Charge magnet, or change the rotor of generator.

3. Find out short circuit position, separate the lines and paint insulating lacquer.

4. Clean slip ring and contacting point, so as to reduce resistance.

5. Replace.

6. Shorten the circuit line or increase the diameter of the wires, so as to reduce circuit electricity loss.

There are not output electric current in AC circuit of the Generator

1. There are circuit break in AC lines of the generator, or the fuse is fused. 

2. There are circuit break in output line.

3. Stator winding is burnt and circuit is broken.

1. Find out the reason, and connect the wires.

2. Find out the beak point then connect the wires.

3. Disassemble, then repair and recover it

AC output is in normal condition, but there is not DC output current 

1. DC fuse is fused.

2. DC output circuit is broken.

3. Rectifier is damaged.

1. Replace.

2. Find out the beak point then connect the wires.

3.  Replace.

Output capacity of the batteries are insufficient

1. Output voltage of the generator is too low, or electricity is generated at all.

2.  The connector of the battery is corroded by acid and the conductivity is weak.

3. Battery is failure

1. Check and eliminate the trouble.

2. Clean the connectors, enable them have a good contact and tighten the connectors.

3. Replace the damaged battery